test(RAID Calculator): added test for raid 7 and 70

This commit is contained in:
ShareVB committed 2025-02-23 13:28:48 +01:00
1 parent 53a1c358df
commit 904352a4eb
1 file changed
+52
@@ -83,6 +83,31 @@ describe('raid-calculator', () => {
});
});
describe('RAID 7', () => {
it('should validate correctly (num >= 5)', () => {
expect(raidCalculations.raid_7.validate(5, 0, 0)).toBe(true);
expect(raidCalculations.raid_7.validate(4, 0, 0)).toBe(false);
});
it('should calculate capacity correctly', () => {
expect(raidCalculations.raid_7.capacity(5, 500, 0, 1)).toBe(1000);
expect(raidCalculations.raid_7.capacity(6, 500, 0, 1)).toBe(1500);
expect(raidCalculations.raid_7.capacity(7, 500, 0, 1)).toBe(2000);
});
it('should calculate efficiency correctly', () => {
expect(raidCalculations.raid_7.efficiency(5, 0)).toBe(40);
expect(raidCalculations.raid_7.efficiency(6, 0)).toBe(50);
expect(raidCalculations.raid_7.efficiency(7, 0)).toBe(57.14285714285714);
});
it('should have fault tolerance for 3 drive failures', () => {
expect(raidCalculations.raid_7.fault(5, 500, 1)).toBe('3 drive failures');
expect(raidCalculations.raid_7.fault(6, 500, 1)).toBe('3 drive failures');
expect(raidCalculations.raid_7.fault(7, 500, 1)).toBe('3 drive failures');
});
});
describe('RAID 10', () => {
it('should validate correctly (num >= 4 and even)', () => {
expect(raidCalculations.raid_10.validate(4, 0, 0)).toBe(true);
@@ -145,5 +170,32 @@ describe('raid-calculator', () => {
expect(raidCalculations.raid_60.fault(8, 500, 1)).toBe('2 drive failures per RAID 6 set');
});
});
describe('RAID 70', () => {
it('should validate correctly (num >= 10 and stripeSize >= 5)', () => {
expect(raidCalculations.raid_70.validate(10, 0, 5)).toBe(true);
expect(raidCalculations.raid_70.validate(9, 0, 5)).toBe(false);
expect(raidCalculations.raid_70.validate(10, 0, 4)).toBe(false);
expect(raidCalculations.raid_70.validate(10, 0, 6)).toBe(false);
});
it('should calculate capacity correctly', () => {
expect(raidCalculations.raid_70.capacity(10, 500, 5, 1)).toBe(2000);
expect(raidCalculations.raid_70.capacity(15, 500, 5, 1)).toBe(3000);
expect(raidCalculations.raid_70.capacity(20, 500, 5, 1)).toBe(4000);
});
it('should calculate efficiency correctly', () => {
expect(raidCalculations.raid_70.efficiency(10, 5)).toBe(40);
expect(raidCalculations.raid_70.efficiency(15, 5)).toBe(40);
expect(raidCalculations.raid_70.efficiency(20, 5)).toBe(40);
});
it('should have fault tolerance for 3 drive failures', () => {
expect(raidCalculations.raid_70.fault(10, 500, 1)).toBe('3 drive failures per RAID 7 set');
expect(raidCalculations.raid_70.fault(15, 500, 1)).toBe('3 drive failures per RAID 7 set');
expect(raidCalculations.raid_70.fault(20, 500, 1)).toBe('3 drive failures per RAID 7 set');
});
});
});
});