feat(new tools): 4-20 mA, 0-10 V and analog scaling converters (#596)

Add an Automation category with three tools for PLC programmers and
instrumentation technicians, built on a shared AnalogSignalConverter
component and a tested src/utils/analog-signal.ts module:

- 4-20 mA converter: current <-> engineering value, 4-20 / 0-20 mA, with the
  NAMUR NE 43 loop diagnostic (failure, undefined zone, under/over-range)
- 0-10 V converter: 0-10, 2-10, 0-5, 1-5 and ±10 V, warns below the live
  zero (broken wire)
- Analog scaling calculator: raw PLC values (Siemens 0-27648 / ±27648,
  Schneider 0-10000, 12/15/16 bits) <-> engineering value, with the rounded
  raw value

Three-column layout: input, parameters and output, each side with a gauge and
a coloured status. A swap button inverts the conversion direction and keeps
the operating point. Also shows the y = gain × x + offset formula for the PLC
and a 0-25-50-75-100 % reference table. Ranges are validated (min < max).

English and French translations.
This commit is contained in:
AlgoVeria authored and GitHub committed 2026-11-08 18:45:54 +01:00
1 parent e7758934a8
commit b5eace85db
15 files changed
+1137

No files matched your search

+135
View File
@@ -0,0 +1,135 @@
<script setup lang="ts">
import { useThemeVars } from 'naive-ui';
import { formatSignalNumber } from '@/utils/analog-signal';
const props = withDefaults(
defineProps<{
min: number;
max: number;
value: number;
unit?: string;
status?: 'ok' | 'warning' | 'error';
}>(),
{
unit: '',
status: 'ok',
},
);
const themeVars = useThemeVars();
const isValid = computed(() => Number.isFinite(props.min) && Number.isFinite(props.max) && props.min !== props.max);
// Position in the range, in percent; may go outside of 0-100 when the value is out of range.
const percent = computed(() =>
isValid.value && Number.isFinite(props.value)
? ((props.value - props.min) / (props.max - props.min)) * 100
: Number.NaN,
);
const clampedPercent = computed(() => (Number.isFinite(percent.value) ? Math.min(100, Math.max(0, percent.value)) : 0));
const isOutOfRange = computed(() => percent.value < 0 || percent.value > 100);
const fillColor = computed(
() =>
({
ok: themeVars.value.primaryColor,
warning: themeVars.value.warningColor,
error: themeVars.value.errorColor,
})[props.status],
);
const withUnit = (value: number) => `${formatSignalNumber(value)}${props.unit ? ` ${props.unit}` : ''}`;
const middle = computed(() => (props.min + props.max) / 2);
</script>
<template>
<div class="analog-gauge" :class="{ 'out-of-range': isOutOfRange }" data-test-id="gauge">
<div class="scale">
<span>{{ withUnit(max) }}</span>
<span>{{ withUnit(middle) }}</span>
<span>{{ withUnit(min) }}</span>
</div>
<div class="tube" role="meter" :aria-valuemin="min" :aria-valuemax="max" :aria-valuenow="value">
<div class="fill" :style="{ height: `${clampedPercent}%`, backgroundColor: fillColor }" />
<div class="tick" style="bottom: 25%" />
<div class="tick" style="bottom: 50%" />
<div class="tick" style="bottom: 75%" />
</div>
<div class="marker-track">
<div v-if="Number.isFinite(percent)" class="marker" :style="{ bottom: `${clampedPercent}%`, color: fillColor }">
◄ {{ formatSignalNumber(percent, 1) }} %
</div>
</div>
</div>
</template>
<style scoped lang="less">
.analog-gauge {
display: flex;
align-items: stretch;
justify-content: center;
gap: 8px;
height: 200px;
margin: 16px 0;
.scale {
display: flex;
flex-direction: column;
justify-content: space-between;
align-items: flex-end;
font-size: 12px;
opacity: 0.7;
white-space: nowrap;
// Labels sit on the top, middle and bottom lines of the tube
margin: -8px 0;
}
.tube {
position: relative;
width: 28px;
border-radius: 6px;
overflow: hidden;
background-color: v-bind('themeVars.buttonColor2');
border: 1px solid v-bind('themeVars.borderColor');
.fill {
position: absolute;
bottom: 0;
left: 0;
right: 0;
transition:
height 0.25s ease-out,
background-color 0.25s;
}
.tick {
position: absolute;
left: 0;
width: 8px;
height: 1px;
background-color: v-bind('themeVars.textColor3');
}
}
.marker-track {
position: relative;
width: 72px;
.marker {
position: absolute;
left: 0;
transform: translateY(50%);
font-size: 12px;
font-weight: 600;
white-space: nowrap;
transition: bottom 0.25s ease-out;
}
}
&.out-of-range .tube {
border-color: v-bind('fillColor');
}
}
</style>
+468
View File
@@ -0,0 +1,468 @@
<script setup lang="ts">
import { useStorage } from '@vueuse/core';
import { useThemeVars } from 'naive-ui';
import { useI18n } from 'vue-i18n';
import AnalogGauge from './AnalogGauge.vue';
import { useCopy } from '@/composable/copy';
import {
type SignalRange,
formatSignalNumber,
getCurrentLoopStatus,
getLinearTransform,
getSignalRangeStatus,
scaleValue,
} from '@/utils/analog-signal';
export interface SignalPreset {
label: string;
min: number;
max: number;
}
type Direction = 'signal-to-value' | 'value-to-signal';
type Side = 'signal' | 'engineering';
interface SideStatus {
type: 'ok' | 'warning' | 'error';
message: string;
}
const props = withDefaults(
defineProps<{
storageKey: string;
signalLabel: string;
signalUnit?: string;
presets: SignalPreset[];
defaultEngineering?: SignalRange & { unit: string };
// The signal is an integer register (raw PLC value): also show the rounded value.
integerSignal?: boolean;
// Apply the NAMUR NE 43 diagnostic when the signal range is 4-20 mA.
currentLoopDiagnostic?: boolean;
}>(),
{
signalUnit: '',
defaultEngineering: () => ({ min: 0, max: 100, unit: '%' }),
integerSignal: false,
currentLoopDiagnostic: false,
},
);
const { t, locale } = useI18n();
const themeVars = useThemeVars();
const defaultPreset = props.presets[0] ?? { label: '', min: 0, max: 10 };
const signalMin = useStorage<number | null>(`${props.storageKey}:signal-min`, defaultPreset.min);
const signalMax = useStorage<number | null>(`${props.storageKey}:signal-max`, defaultPreset.max);
const engineeringMin = useStorage<number | null>(`${props.storageKey}:engineering-min`, props.defaultEngineering.min);
const engineeringMax = useStorage<number | null>(`${props.storageKey}:engineering-max`, props.defaultEngineering.max);
const engineeringUnit = useStorage(`${props.storageKey}:engineering-unit`, props.defaultEngineering.unit);
const direction = useStorage<Direction>(`${props.storageKey}:direction`, 'signal-to-value');
const toNumber = (value: number | null | undefined) => (typeof value === 'number' ? value : Number.NaN);
const signalRange = computed<SignalRange>(() => ({ min: toNumber(signalMin.value), max: toNumber(signalMax.value) }));
const engineeringRange = computed<SignalRange>(() => ({
min: toNumber(engineeringMin.value),
max: toNumber(engineeringMax.value),
}));
const rangeOf = (side: Side) => (side === 'signal' ? signalRange.value : engineeringRange.value);
const unitOf = (side: Side) => (side === 'signal' ? props.signalUnit : engineeringUnit.value);
const labelOf = (side: Side) =>
side === 'signal' ? props.signalLabel : t('analogSignalConverter.texts.label-engineering-value');
const inputSide = computed<Side>(() => (direction.value === 'signal-to-value' ? 'signal' : 'engineering'));
const outputSide = computed<Side>(() => (direction.value === 'signal-to-value' ? 'engineering' : 'signal'));
const midpoint = ({ min, max }: SignalRange) => (min + max) / 2;
const inputValue = ref<number | null>(midpoint(rangeOf(inputSide.value)));
// Min must be strictly lower than max: an inverted range is almost always a typo.
const isRangeValid = (range: SignalRange) =>
Number.isFinite(range.min) && Number.isFinite(range.max) && range.min < range.max;
const isSignalRangeInvalid = computed(() => !isRangeValid(signalRange.value));
const isEngineeringRangeInvalid = computed(() => !isRangeValid(engineeringRange.value));
const rangesError = computed(() => {
if (!isRangeValid(signalRange.value)) {
return t('analogSignalConverter.texts.error-signal-range');
}
if (!isRangeValid(engineeringRange.value)) {
return t('analogSignalConverter.texts.error-engineering-range');
}
return '';
});
const outputValue = computed(() => {
const value = toNumber(inputValue.value);
if (rangesError.value || !Number.isFinite(value)) {
return Number.NaN;
}
return scaleValue({ value, from: rangeOf(inputSide.value), to: rangeOf(outputSide.value) });
});
const valueOf = (side: Side) => (side === inputSide.value ? toNumber(inputValue.value) : outputValue.value);
// Swapping keeps the current operating point: the output becomes the new input.
function swapDirection() {
const previousOutput = outputValue.value;
direction.value = direction.value === 'signal-to-value' ? 'value-to-signal' : 'signal-to-value';
inputValue.value = Number.isFinite(previousOutput)
? Number(formatSignalNumber(previousOutput))
: midpoint(rangeOf(inputSide.value));
}
const CUSTOM_PRESET = 'custom';
const presetOptions = computed(() => [
...props.presets.map(({ label }, index) => ({ label, value: String(index) })),
{ label: t('analogSignalConverter.texts.preset-custom'), value: CUSTOM_PRESET },
]);
const selectedPreset = computed({
get() {
const index = props.presets.findIndex(({ min, max }) => min === signalMin.value && max === signalMax.value);
return index === -1 ? CUSTOM_PRESET : String(index);
},
set(value: string) {
const preset = props.presets[Number(value)];
if (preset) {
signalMin.value = preset.min;
signalMax.value = preset.max;
}
},
});
const isCurrentLoop = computed(
() => props.currentLoopDiagnostic && signalRange.value.min === 4 && signalRange.value.max === 20,
);
function getSignalStatus(value: number): SideStatus {
if (isCurrentLoop.value) {
const status = getCurrentLoopStatus(value);
if (status === 'ok') {
return { type: 'ok', message: t('analogSignalConverter.texts.status-ok') };
}
return {
type: status.startsWith('failure') ? 'error' : 'warning',
message: t(`analogSignalConverter.texts.loop-status-${status}`),
};
}
const status = getSignalRangeStatus({ value, range: signalRange.value });
if (status === 'ok') {
return { type: 'ok', message: t('analogSignalConverter.texts.status-ok') };
}
// A live zero (e.g. 2-10 V) lets a value under the minimum reveal a broken wire.
const hasLiveZero = Math.min(signalRange.value.min, signalRange.value.max) > 0;
return {
type: 'warning',
message:
status === 'below-range' && hasLiveZero
? t('analogSignalConverter.texts.status-below-live-zero')
: t(`analogSignalConverter.texts.status-${status}`),
};
}
function getEngineeringStatus(value: number): SideStatus {
const status = getSignalRangeStatus({ value, range: engineeringRange.value });
return status === 'ok'
? { type: 'ok', message: t('analogSignalConverter.texts.status-ok') }
: { type: 'warning', message: t(`analogSignalConverter.texts.engineering-${status}`) };
}
function statusOf(side: Side): SideStatus | null {
const value = valueOf(side);
if (rangesError.value || !Number.isFinite(value)) {
return null;
}
return side === 'signal' ? getSignalStatus(value) : getEngineeringStatus(value);
}
const inputStatus = computed(() => statusOf(inputSide.value));
const outputStatus = computed(() => statusOf(outputSide.value));
const formatWithUnit = (value: number, unit: string) =>
Number.isFinite(value) ? `${formatSignalNumber(value)}${unit ? ` ${unit}` : ''}` : '';
const withUnit = (label: string, unit: string) => (unit ? `${label} (${unit})` : label);
const outputText = computed(() => formatWithUnit(outputValue.value, unitOf(outputSide.value)));
const roundedOutputText = computed(() =>
props.integerSignal && outputSide.value === 'signal' && Number.isFinite(outputValue.value)
? formatWithUnit(Math.round(outputValue.value), props.signalUnit)
: '',
);
const { copy: copyOutput } = useCopy({ source: () => formatSignalNumber(outputValue.value) });
// Significant digits rather than decimals: Siemens gains such as 100 / 27648 are tiny.
const formatCoefficient = (value: number) => String(Number(value.toPrecision(10)));
const formula = computed(() => {
if (rangesError.value) {
return '';
}
const { gain, offset } = getLinearTransform({ from: rangeOf(inputSide.value), to: rangeOf(outputSide.value) });
const names = {
signal: t('analogSignalConverter.texts.formula-signal'),
engineering: t('analogSignalConverter.texts.formula-value'),
};
const product = `${names[outputSide.value]} = ${formatCoefficient(gain)} × ${names[inputSide.value]}`;
return formatCoefficient(offset) === '0'
? product
: `${product} ${offset < 0 ? '-' : '+'} ${formatCoefficient(Math.abs(offset))}`;
});
const referencePoints = computed(() => {
if (rangesError.value) {
return [];
}
return [0, 25, 50, 75, 100].map((percent) => {
const signal = scaleValue({ value: percent, from: { min: 0, max: 100 }, to: signalRange.value });
const value = scaleValue({ value: percent, from: { min: 0, max: 100 }, to: engineeringRange.value });
return {
percent: `${percent} %`,
signal: formatWithUnit(props.integerSignal ? Math.round(signal) : signal, props.signalUnit),
value: formatWithUnit(value, engineeringUnit.value),
};
});
});
</script>
<template>
<div flex flex-col gap-3>
<div class="converter-columns">
<!-- Input -->
<c-card class="column" :title="t('analogSignalConverter.texts.title-input')">
<div class="side-label">
{{ withUnit(labelOf(inputSide), unitOf(inputSide)) }}
</div>
<n-input-number-i18n v-model:value="inputValue" size="large" data-test-id="converter-input" />
<AnalogGauge
v-if="!rangesError"
:min="rangeOf(inputSide).min"
:max="rangeOf(inputSide).max"
:value="valueOf(inputSide)"
:unit="unitOf(inputSide)"
:status="inputStatus?.type"
data-test-id="input-gauge"
/>
<div v-if="inputStatus" class="status" :class="inputStatus.type" data-test-id="input-status">
<icon-mdi-check-circle v-if="inputStatus.type === 'ok'" />
<icon-mdi-alert v-else />
<span>{{ inputStatus.message }}</span>
</div>
</c-card>
<!-- Parameters -->
<c-card class="column" :title="t('analogSignalConverter.texts.title-parameters')">
<!-- c-select keeps the label it was mounted with: remount it when the language changes -->
<c-select
:key="locale"
v-model:value="selectedPreset"
:options="presetOptions"
:label="t('analogSignalConverter.texts.label-signal-type')"
data-test-id="signal-preset"
/>
<div class="side-label" mt-3>
{{ withUnit(`${signalLabel} min / max`, signalUnit) }}
</div>
<div flex gap-2>
<n-input-number-i18n
v-model:value="signalMin"
:status="isSignalRangeInvalid ? 'error' : undefined"
flex-1
:show-button="false"
data-test-id="signal-min"
/>
<n-input-number-i18n
v-model:value="signalMax"
:status="isSignalRangeInvalid ? 'error' : undefined"
flex-1
:show-button="false"
data-test-id="signal-max"
/>
</div>
<div class="swap" my-4>
<c-button
round
:title="t('analogSignalConverter.texts.swap-direction')"
data-test-id="swap-direction"
@click="swapDirection"
>
<icon-mdi-swap-horizontal text-20px />
<span ml-2>{{ t('analogSignalConverter.texts.swap-direction') }}</span>
</c-button>
</div>
<div class="side-label">
{{ t('analogSignalConverter.texts.label-engineering-range') }}
</div>
<div flex gap-2>
<n-input-number-i18n
v-model:value="engineeringMin"
:status="isEngineeringRangeInvalid ? 'error' : undefined"
flex-1
:show-button="false"
data-test-id="engineering-min"
/>
<n-input-number-i18n
v-model:value="engineeringMax"
:status="isEngineeringRangeInvalid ? 'error' : undefined"
flex-1
:show-button="false"
data-test-id="engineering-max"
/>
</div>
<c-input-text
v-model:value="engineeringUnit"
:label="t('analogSignalConverter.texts.label-engineering-unit')"
:placeholder="t('analogSignalConverter.texts.placeholder-unit')"
mt-3
data-test-id="engineering-unit"
/>
<c-alert v-if="rangesError" type="error" mt-3>
{{ rangesError }}
</c-alert>
<input-copyable
v-else
:label="t('analogSignalConverter.texts.label-formula')"
:value="formula"
mt-3
data-test-id="formula"
/>
</c-card>
<!-- Output -->
<c-card class="column" :title="t('analogSignalConverter.texts.title-output')">
<div class="side-label">
{{ withUnit(labelOf(outputSide), unitOf(outputSide)) }}
</div>
<div class="output-value">
<span data-test-id="converter-output">{{ outputText || '—' }}</span>
<c-button
v-if="outputText"
variant="text"
circle
:title="t('analogSignalConverter.texts.copy-output')"
@click="copyOutput()"
>
<icon-mdi-content-copy />
</c-button>
</div>
<div v-if="roundedOutputText" class="rounded-output" data-test-id="converter-output-rounded">
{{ t('analogSignalConverter.texts.label-rounded-signal') }} : {{ roundedOutputText }}
</div>
<AnalogGauge
v-if="!rangesError"
:min="rangeOf(outputSide).min"
:max="rangeOf(outputSide).max"
:value="outputValue"
:unit="unitOf(outputSide)"
:status="outputStatus?.type"
data-test-id="output-gauge"
/>
<div v-if="outputStatus" class="status" :class="outputStatus.type" data-test-id="output-status">
<icon-mdi-check-circle v-if="outputStatus.type === 'ok'" />
<icon-mdi-alert v-else />
<span>{{ outputStatus.message }}</span>
</div>
</c-card>
</div>
<c-card v-if="!rangesError" :title="t('analogSignalConverter.texts.title-reference-points')">
<n-table size="small" data-test-id="reference-points">
<thead>
<tr>
<th>{{ t('analogSignalConverter.texts.column-percent') }}</th>
<th>{{ signalLabel }}</th>
<th>{{ t('analogSignalConverter.texts.label-engineering-value') }}</th>
</tr>
</thead>
<tbody>
<tr v-for="point of referencePoints" :key="point.percent">
<td>{{ point.percent }}</td>
<td>{{ point.signal }}</td>
<td>{{ point.value }}</td>
</tr>
</tbody>
</n-table>
</c-card>
</div>
</template>
<style scoped lang="less">
.converter-columns {
display: grid;
grid-template-columns: 1fr 1.2fr 1fr;
gap: 12px;
align-items: stretch;
// Narrow screens: input, parameters and output stacked
@media (max-width: 900px) {
grid-template-columns: 1fr;
}
.column {
min-width: 0;
}
}
.side-label {
font-size: 13px;
opacity: 0.75;
margin-bottom: 6px;
}
.swap {
display: flex;
justify-content: center;
}
.output-value {
display: flex;
align-items: center;
justify-content: center;
gap: 4px;
min-height: 40px;
font-size: 28px;
font-weight: 600;
word-break: break-all;
}
.rounded-output {
text-align: center;
font-size: 13px;
opacity: 0.75;
}
.status {
display: flex;
align-items: flex-start;
gap: 6px;
font-size: 13px;
line-height: 1.4;
svg {
flex-shrink: 0;
margin-top: 2px;
}
&.ok {
color: v-bind('themeVars.successColor');
}
&.warning {
color: v-bind('themeVars.warningColor');
}
&.error {
color: v-bind('themeVars.errorColor');
}
}
</style>