synced 2026-11-20 21:23:08 +03:00
feat(new tool): RAID Reliability Calculator/MTTDL
This commit is contained in:
1 parent
6b1825f568
commit
dbb56a4db6
2 files changed
+200
No files matched your search
@@ -0,0 +1,13 @@
|
||||
import { SpeedFilled } from '@vicons/material';
|
||||
import { defineTool } from '../tool';
|
||||
|
||||
export const tool = defineTool({
|
||||
name: 'RAID Reliability Calculator',
|
||||
path: '/mttdl-calculator',
|
||||
description: 'Computes storage system reliability using well-known MTTDL methodology',
|
||||
keywords: ['mttdl', 'raid', 'reliability', 'calculator'],
|
||||
component: () => import('./mttdl-calculator.vue'),
|
||||
icon: SpeedFilled,
|
||||
createdAt: new Date('2025-08-15'),
|
||||
category: 'Network',
|
||||
});
|
||||
@@ -0,0 +1,187 @@
|
||||
<script setup>
|
||||
const form = ref({
|
||||
raidLevel: 'RAID 5',
|
||||
numDrives: 6,
|
||||
mtbf: 1000000,
|
||||
rebuildTime: 24,
|
||||
ber: -15,
|
||||
driveCapacityTB: 4,
|
||||
yearsToSimulate: 5,
|
||||
});
|
||||
|
||||
const raidOptions = [
|
||||
{ label: 'RAID 0', value: 'RAID 0' },
|
||||
{ label: 'RAID 1', value: 'RAID 1' },
|
||||
{ label: 'RAID 5', value: 'RAID 5' },
|
||||
{ label: 'RAID 6', value: 'RAID 6' },
|
||||
{ label: 'RAID 10', value: 'RAID 10' },
|
||||
{ label: 'RAID-Z1', value: 'RAID-Z1' },
|
||||
{ label: 'RAID-Z2', value: 'RAID-Z2' },
|
||||
{ label: 'RAID-Z3', value: 'RAID-Z3' },
|
||||
{ label: 'RAID 50', value: 'RAID 50' },
|
||||
];
|
||||
|
||||
function basicMTTDL(raidLevel, numDrives, mtbf, rebuildTime) {
|
||||
const λ = 1 / mtbf;
|
||||
switch (raidLevel) {
|
||||
case 'RAID 0':
|
||||
return mtbf / numDrives;
|
||||
case 'RAID 1':
|
||||
return mtbf / (numDrives * (numDrives - 1));
|
||||
case 'RAID 5':
|
||||
return mtbf / (numDrives * (numDrives - 1) * λ * rebuildTime);
|
||||
case 'RAID 6':
|
||||
return mtbf / (numDrives * (numDrives - 1) * (numDrives - 2) * λ * rebuildTime);
|
||||
case 'RAID 10':
|
||||
return mtbf / (numDrives / 2);
|
||||
default:
|
||||
return 0;
|
||||
}
|
||||
}
|
||||
|
||||
function getMTTDL({ raidLevel, numDrives, mtbf, rebuildTime, ber, driveCapacityTB }) {
|
||||
const λ = 1 / mtbf;
|
||||
const bitsPerDrive = driveCapacityTB * 1e12 * 8;
|
||||
const unrecoverableReadProb = 1 - (1 - 10 ** ber) ** bitsPerDrive;
|
||||
const groupSize = 5;
|
||||
const numGroups = Math.floor(numDrives / groupSize);
|
||||
|
||||
switch (raidLevel) {
|
||||
case 'RAID-Z1':
|
||||
return mtbf / (numDrives * (numDrives - 1) * λ * rebuildTime * unrecoverableReadProb);
|
||||
case 'RAID-Z2':
|
||||
return mtbf / (numDrives * (numDrives - 1) * (numDrives - 2) * λ * rebuildTime * unrecoverableReadProb);
|
||||
case 'RAID-Z3':
|
||||
return mtbf / (numDrives * (numDrives - 1) * (numDrives - 2) * (numDrives - 3) * λ * rebuildTime * unrecoverableReadProb);
|
||||
case 'RAID 50':
|
||||
return mtbf / (numGroups * groupSize * (groupSize - 1) * λ * rebuildTime);
|
||||
default:
|
||||
return basicMTTDL(raidLevel, numDrives, mtbf, rebuildTime);
|
||||
}
|
||||
}
|
||||
|
||||
const computedMTTDL = computed(() => {
|
||||
const hours = getMTTDL(form.value);
|
||||
return {
|
||||
hours,
|
||||
years: hours / 8760,
|
||||
};
|
||||
});
|
||||
|
||||
function simulateFailureProbability(mttdl, years) {
|
||||
const hours = years * 365.25 * 24;
|
||||
return 1 - Math.exp(-hours / mttdl);
|
||||
}
|
||||
|
||||
const failureProbability = computed(() =>
|
||||
simulateFailureProbability(computedMTTDL.value.hours, form.value.yearsToSimulate),
|
||||
);
|
||||
</script>
|
||||
|
||||
<template>
|
||||
<NCard title="MTTDL & Failure Probability Calculator" style="max-width: 600px; margin: auto;">
|
||||
<NForm :model="form" label-width="190px" label-placement="left">
|
||||
<NFormItem label="RAID Level:">
|
||||
<NSelect v-model:value="form.raidLevel" :options="raidOptions" placeholder="Select RAID level" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Number of Drives:">
|
||||
<NInputNumber v-model:value="form.numDrives" :min="1" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Drive MTBF (hours):">
|
||||
<NInputNumber v-model:value="form.mtbf" :min="1" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Rebuild Time (hours):">
|
||||
<NInputNumber v-model:value="form.rebuildTime" :min="1" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Bit Error Rate (BER in 1eX):">
|
||||
<NInputNumber v-model:value="form.ber" :min="-18" :max="-6" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Drive Capacity (TB):">
|
||||
<NInputNumber v-model:value="form.driveCapacityTB" :min="1" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Years for Failure probability:">
|
||||
<NInputNumber v-model:value="form.yearsToSimulate" :min="1" />
|
||||
</NFormItem>
|
||||
|
||||
<NDivider />
|
||||
|
||||
<NFormItem label="MTTDL (hours):">
|
||||
<input-copyable :value="computedMTTDL.hours.toFixed(2)" />
|
||||
</NFormItem>
|
||||
<NFormItem label="MTTDL (years):">
|
||||
<input-copyable :value="computedMTTDL.years.toFixed(2)" />
|
||||
</NFormItem>
|
||||
<NFormItem label="Failure Probability:">
|
||||
<input-copyable :value="`${(failureProbability * 100).toFixed(4)}%`" />
|
||||
</NFormItem>
|
||||
|
||||
<NDivider />
|
||||
|
||||
<details>
|
||||
<summary>🧠 Key Terms Explained</summary>
|
||||
|
||||
<h3>💾 RAID Level</h3>
|
||||
<p>RAID (Redundant Array of Independent Disks) is a method of combining multiple physical drives into one logical unit to improve performance, redundancy, or both.</p>
|
||||
<table border="1" cellpadding="8" cellspacing="0">
|
||||
<thead>
|
||||
<tr>
|
||||
<th>RAID Level</th>
|
||||
<th>Description</th>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
<tr>
|
||||
<td>RAID 0</td>
|
||||
<td>Striping only. No redundancy. Fast but risky—if one drive fails, all data is lost.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID 1</td>
|
||||
<td>Mirroring. Data is duplicated across drives. High redundancy, low capacity efficiency.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID 5</td>
|
||||
<td>Striping with parity. Can tolerate one drive failure. Balanced speed and redundancy.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID 6</td>
|
||||
<td>Double parity. Can survive two drive failures.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID 10</td>
|
||||
<td>Mirrored pairs striped together. High performance and redundancy.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID-Z1/Z2/Z3</td>
|
||||
<td>ZFS-based RAID levels with single, double, or triple parity. Designed for data integrity.</td>
|
||||
</tr>
|
||||
<tr>
|
||||
<td>RAID 50</td>
|
||||
<td>Stripe of RAID 5 arrays. Combines performance of RAID 0 with redundancy of RAID 5.</td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
|
||||
<h3>⏱️ MTBF (Mean Time Between Failures)</h3>
|
||||
<p>The average time (in hours) a drive is expected to operate before failing. Higher MTBF means more reliable hardware.</p>
|
||||
|
||||
<h3>🔁 Rebuild Time</h3>
|
||||
<p>The time required to reconstruct data on a replacement drive after a failure. Longer rebuild times increase the risk of a second failure during recovery.</p>
|
||||
|
||||
<h3>📉 MTTDL (Mean Time To Data Loss)</h3>
|
||||
<p>A statistical estimate of how long a RAID system can operate before data loss occurs. It considers drive failures, rebuild time, and RAID redundancy. Higher MTTDL means a safer system.</p>
|
||||
|
||||
<h3>🧮 Bit Error Rate (BER)</h3>
|
||||
<p>The probability that a bit read from a disk will be incorrect due to hardware limitations. Even tiny BERs (like 1 in a trillion) can cause issues during rebuilds, especially with large drives.</p>
|
||||
|
||||
<h3>🧠 Unrecoverable Read Error (URE)</h3>
|
||||
<p>Occurs when a drive fails to read a sector during rebuild. BER contributes to URE risk, which can compromise RAID recovery.</p>
|
||||
|
||||
<h3>📦 Drive Capacity (TB)</h3>
|
||||
<p>Total storage per drive. Larger drives take longer to rebuild and are more susceptible to BER-related errors.</p>
|
||||
|
||||
<h3>📈 Failure Probability</h3>
|
||||
<p>The chance that the RAID system will experience data loss over a given time period (e.g., 5 years). Calculated using MTTDL and exponential failure models.</p>
|
||||
</details>
|
||||