Files
it-tools/src/utils
AlgoVeria b5eace85db feat(new tools): 4-20 mA, 0-10 V and analog scaling converters (#596)
Add an Automation category with three tools for PLC programmers and
instrumentation technicians, built on a shared AnalogSignalConverter
component and a tested src/utils/analog-signal.ts module:

- 4-20 mA converter: current <-> engineering value, 4-20 / 0-20 mA, with the
  NAMUR NE 43 loop diagnostic (failure, undefined zone, under/over-range)
- 0-10 V converter: 0-10, 2-10, 0-5, 1-5 and ±10 V, warns below the live
  zero (broken wire)
- Analog scaling calculator: raw PLC values (Siemens 0-27648 / ±27648,
  Schneider 0-10000, 12/15/16 bits) <-> engineering value, with the rounded
  raw value

Three-column layout: input, parameters and output, each side with a gauge and
a coloured status. A swap button inverts the conversion direction and keeps
the operating point. Also shows the y = gain × x + offset formula for the PLC
and a 0-25-50-75-100 % reference table. Ranges are validated (min < max).

English and French translations.